I would then run the uf b cable along the bottom of the deck to where it would eventually be buried for about 8 ft.
Uf b wire in conduit.
Wiring in pvc conduit must have at least.
Burying the cable 24 inches requires more digging so this method only makes sense if you have easy to dig soil or are renting a trench digger.
Running uf cable through metal or pvc conduit.
At 24 in deep run direct bury uf b wire cable.
Type uf cable is the most commonly used nonmetallic cable for residential outdoor wiring runs.
Uf cable can be direct buried without conduit with a minimum of 24 inches of earth cover.
Out of an underground trench that is 24 inches deep.
I want to use non metallic conduit from the bottom of the panel to reach under my elevated deck about 5 ft.
It needs a conduit where the cable is exposed on the outside of the house and to 18 inches below the ground.
Always run a grounding wire even when rigid metal conduit is allowed as the ground since the metal corrodes and the ground will be lost.
I further plan to use uf b cable.
Uf cable should not be installed into conduit with the exception of short distances such as the following.
Although not commonly done it is allowable to run uf cable but not nm cable through.
Here the conduit must be at least 18 inches deep and again the individual conducting wires inside the conduit should carry a w waterproof rating such as thwn 2.
Where a pvc conduit may sleeve the uf cable as it leads up out of the ground to an electrical box.
Conduit is always convienent since you can run extra hot wires ex.
Wiring buried inside rigid metal rmc or intermediate metal imc conduit must have at least 6 inches of earth cover.
Uf in conduit for short sections only if a complete conduit system then individual thwn wires are used.
More about electrical wiring.
Electrical wire for the home.
I would feed the uf b cable into the conduit and terminate in the panel cb.